Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian Heart J ; 75(6): 469-472, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37951304

RESUMO

The registry reports 3-year safety and clinical performance of the ultrathin strut (60 µm) biodegradable polymer-coated Tetrilimus, an everolimus-eluting stent (EES) (Sahajanand Medical Technologies Limited, India), in 'real-world' patients with coronary artery disease. A total of 815 Tetrilimus EES were implanted in 735 lesions in 594 patients. At 3-year follow-up, primary endpoint (target lesion failure, TLF) was reported in 8.6 % patients, including 2.6 % cardiac deaths, 3.5 % myocardial infarction and 2.6 % target lesion revascularization. At three-year, no cases of definite stent thrombosis were reported. The final three-year results of PERFORM-EVER registry endorse the continuous safety and effectiveness Tetrilimus EES.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Everolimo/farmacologia , Sirolimo/farmacologia , Resultado do Tratamento , Stents , Polímeros , Implantes Absorvíveis , Sistema de Registros , Desenho de Prótese
2.
Anatol J Cardiol ; 26(8): 619-628, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35924288

RESUMO

BACKGROUND: Tetrilimus (Sahajanand Medical Technologies Limited, Surat, India) is a biodegradable polymer-coated everolimus-eluting stent with cobalt-chromium stent platform and ultra-thin (60 µm) strut thickness. We aimed to report 1-year safety and clinical performance of Tetrilimus everolimus-eluting stent in patients with coronary artery disease in "real-world" clinical practice. METHODS: The PERFORMance of biodegradable polymer-coated ultra-thin EVERolimuseluting stents was an observational, multicenter, single-arm, and investigator-initiated retrospective registry. All "real-world" patients who had received Tetrilimus everolimuseluting stent between July-2015 and October-2016 at four study centers were analyzed. The data were collected retrospectively either by extraction from existing databases in consecutive fashion where index and follow-up data existed or the follow-up was obtained by telephonic contact. Primary endpoint was 1-year incidence of target lesion failure, which was defined as a composite endpoint of cardiac death, myocardial infarction, and target lesion revascularization by percutaneous or surgical methods. The Academic Research Consortium-defined stent thrombosis was assessed as additional safety endpoint. RESULTS: During the study period, 815 Tetrilimus everolimus-eluting stents (1.4 ± 0.5 stent/ patient) were implanted to treat 735 coronary lesions (1.1 ± 0.3 stent/lesion) in 594 patients (mean age: 55.6 ± 12.1 years). The cumulative incidence of target lesion failure at 1-year follow-up was 3.7%, which included 9 (1.5%) cardiac deaths, 8 (1.4%) myocardial infarctions, and 5 (0.8%) target lesion revascularizations. There were 5 (0.8%) cases of probable stent thrombosis and 4 (0.7%) cases of possible stent thrombosis at 1-year follow-up. CONCLUSION: Low incidences of target lesion failure and stent thrombosis at 1-year followup indicates that biodegradable polymer-coated ultra-thin Tetrilimus everolimus-eluting stents may have encouraging safety and efficacy in unselected real-world patients with coronary artery disease, including those with high-risk characteristics and complex lesions.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Implantes Absorvíveis , Adulto , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos/efeitos adversos , Everolimo/farmacologia , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Sirolimo/farmacologia , Stents/efeitos adversos , Trombose/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...